Protocol - Cardiorespiratory Fitness - Exercise Test Estimate - Treadmill Test

Add to Toolkit

Protocol Name from Source:

Ebbeling, E. B., Ward, A. Puleo, E. M., Widrick, J., & Rippe, J. M. (1991). Development of a single-stage submaximal treadmill walking test. Medicine and Science in Sports and Exercise, 23(8), 966-973.

Availability:

Publicly available

Description:

The participant is asked to walk on a treadmill at a 5% grade for 4 minutes. A technician utilizes a stopwatch to time the walk. Although the test was validated on participants with a range of fitness, it may tend to underestimate fitness in highly trained individuals. The participant wears a heart-rate (HR) monitor that records HR continuously through the test. After the test is completed, the technician records the HR from the last 15 seconds of the test. In addition, the participant’s age and gender are needed to complete an equation to determine maximal oxygen consumption (VO2 max).

Protocol:

Treadmill

Secure the heart-rate monitor chest strap and wrist receiver. Ask the study participant to warm up by walking on a treadmill at 0% grade at a brisk, but comfortable pace of 2 to 4.5 mph for 4 minutes. The warm up pace should produce a heart rate that is 50-70% of the age-predicted maximum HR (220 - age in years). After 4 minutes at 0% grade, begin the test by increasing the grade of the treadmill to 5%, start the stopwatch. The speed should remain the same for 4 minutes at the 5% grade. Heart rate from a HR monitor should be obtained for the last 15 sec of the test. Record the speed, HR, age, and gender into the following scoring equation to determine predicted relative VO2max (maximal oxygen consumption).

Scoring

VO2max = 15.1 + 21.8*SPEED (mph) - 0.327* HEART RATE (bpm) - 0.263*SPEED*AGE (yrs) + 0.00504*HEART RATE*AGE + 5.98*GENDER

(0 = female, 1 = male)

Units are milliliters of oxygen per kilogram body weight per minute expressed as mil/kg/min.

Personnel and Training Required

A technician who has been trained in monitoring a treadmill test and in properly recording the data.

Equipment Needs

Treadmill

A heart-rate (HR) monitor with chest strap and wrist receiver that stores HR data is recommended.

Requirements

Requirement CategoryRequired
Average time of greater than 15 minutes in an unaffected individualNo
Major equipmentNo
Specialized requirements for biospecimen collectionNo
Specialized trainingNo

Mode of Administration

Self-administered

Life Stage:

Adult, Senior

Specific Instructions:

A heart-rate (HR) monitor (e.g. Polar® HR monitor) should be used because the HR that is used in the equation is taken during the last 15 seconds of the test and not after the test is completed (HR will decline rapidly after test is completed). If HR is taken after the test is completed, this will introduce error to the prediction of VO2 max.

Ideally, the HR monitor should store HR so the technician can easily access the results after the test is completed. If not, the technician can read and record the HR value directly from the receiver in the last 15 seconds of the test. The manufacturer’s user manual should be followed for proper calibration and usage.

The participant should complete a screening instrument such as the PAR-Q+ (Physical Activity Readiness Questionnaire for Everyone, Canadian Society for Exercise Physiology) prior to the treadmill test to make certain he or she is physically capable of performing the test. If the person is elderly or in poor health, a physician’s examination and approval is preferable prior to the test.

Polar® is a trademark of Polar Electro Oy.

Research Domain Information

Release Date:

October 1, 2015

Definition

A measure to estimate maximal oxygen consumption (VO2 max).

Purpose

Aerobic capacity (VO2 max) is the best indicator of a person’s cardiovascular fitness and aerobic endurance. Low VO2 max has been associated with cardiovascular disease.

Selection Rationale

This is a standard assessment of aerobic capacity that has been widely utilized for the past two decades. It is low burden for healthy participants and relatively easy for a technician to administer.

Language

English

Standards

StandardNameIDSource
Common Data Elements (CDE)Person Cardiorespiratory Fitness Treadmill Test Estimate Text3060850CDE Browser
Logical Observation Identifiers Names and Codes (LOINC)Cardioresp fitness treadmill proto62815-6LOINC

Process and Review

The [link[phenx.org/node/62|Expert Review Panel #1]] reviewed the measures in the Anthropometrics, Diabetes, Physical Activity and Physical Fitness, and Nutrition and Dietary Supplements domains.

Guidance from the ERP includes:

• Revised descriptions of measure

Back-compatible: no changes to Data Dictionary

Previous version in Toolkit archive ([link[www.phenxtoolkit.org/index.php?pageLink=browse.archive.protocols&id=150000|link]])

Source

Ebbeling, E. B., Ward, A. Puleo, E. M., Widrick, J., & Rippe, J. M. (1991). Development of a single-stage submaximal treadmill walking test. Medicine and Science in Sports and Exercise, 23(8), 966-973.

General References

Physical Activity Readiness Questionnaire for Everyone (PAR-Q+) © 2011. Used with permission from the Canadian Society for Exercise Physiology.

Protocol ID:

150102

Variables:

Export Variables
Variable NameVariable IDVariable DescriptionVersiondbGaP Mapping
PX150102_SexPX150102010000Participant's sex4N/A
PX150102_AgePX150102020000Participant's age4N/A
PX150102_Treadmill_SpeedPX150102030000Treadmill speed during warm up4N/A
PX150102_Heart_Rate_During_WarmupPX150102040000Participant's heart rate during the last 10 minutes of the walk as shown on heart rate monitor4N/A
PX150102_Heart_Rate_During_TestPX150102050000Participant's heart rate during the last 10 minutes of the walk as shown on heart rate monitor4N/A
PX150102_Time_To_Complete_Walk_MinutesPX150102060100Time to complete entire 1 mile walk4Variable Mapping
PX150102_Time_To_Complete_Walk_SecondsPX150102060200Time to complete entire 1 mile walk4Variable Mapping